Pick the family before you pick the product
A glass curtain wall is any non-load-bearing glazed envelope, and every system you will be quoted belongs to one of three families. All-glass walls run on glass fins and patch fittings, with no visible metal frame. Framed walls carry the glass in an aluminium grid that is either visible or hidden behind structural glazing. Point-supported walls hold each pane on spider fittings or tensioned cables. The family decides cost, span and maintenance before any brand does, so fix it first. Starveil Facade fabricates all three families from its Foshan plant, and the delivered curved-glass theatre below shows one family working at civic scale.
A glass curtain wall is a non-structural glazed envelope hung from the building frame, carrying wind, water and its own weight back to the structure through engineered supports. The types of glass curtain wall on the market differ in one variable: what holds the glass. All-glass systems hold panes on glass fins with patch fittings, framed systems hold them in aluminium profiles, and point-supported systems hold them on metal fittings bolted through laminated units. Whatever the family, air, water and structural performance is proven on a mock-up under test methods published by ASTM International.
Three families, and the question each one answers
| Family | How the glass is held | Where it wins | What to watch |
|---|---|---|---|
| All-glass, frameless | Glass fins with patch fittings | Lobbies, showrooms, clear heights 3 to 12 m | No thermal break in the fin; deflection under wind |
| Framed, visible or structurally glazed | Aluminium mullion and transom grid | Repetitive insulated envelopes: offices, hotels, towers | Sealant quality in the glazed variant; frame U-value |
| Point-supported | Spider fittings, cable or truss back-up | Atria, entrances, maximum transparency | Highest cost per m²; point loading on the glass |
The families are not interchangeable, and a glass curtain wall bought by appearance alone is the one that ends in change orders. Span and wind nominate the family; budget and maintenance then confirm it. For the wider family of glazed envelope routes that sit around these three, our curtain glazing systems overview maps the territory.
The all-glass family: fins and patch fittings
A frameless glass curtain wall does the frame’s job in glass. Laminated fins stand vertically behind the glass plane, patch fittings clamp the panes to the fins, and the assembly spans between floor and head with no aluminium grid in sight. It is the family for lobbies, showrooms and civic entrances where the view is the architecture.
The engineering price is real. Fins roughly double the glass weight per bay, wind deflection in a 12 m fin must be calculated rather than assumed, and a glass fin carries no thermal break, so conditioned interiors need the condensation risk addressed at sill and head. How these walls resist wind and seismic action without a frame is covered in our frameless facades wind and seismic load guide.
The framed family: visible and hidden grids
The framed glass curtain wall is the default for insulated commercial envelopes. Mullions and transoms carry the loads, and the glass sits in a drained rebate behind a pressure plate or, in the structurally glazed variant, bonds to the frame with silicone so the outside reads as one flush plane. Both variants close to whole-wall U-values near 1.6 to 2.0 W/(m²·K) with the right insulated units.
The variant choice is a maintenance and safety decision as much as a look. Visible caps can be re-gasketed from outside, floor by floor; structural glazing hides the frame behind a silicone joint whose adhesion is tested per batch, a build-up our structural glazing system page breaks down. The construction route, stick or unitized, then decides where the quality is made, a comparison our stick versus unitized guide runs in full.
The point-supported family: spider fittings and tension structures
Point-supported walls hold each pane on spider fittings, countersunk or through-bolted, with loads carried back by steel tubes, cable trusses or tensioned rods. Spans reach 20 m without a visible grid, which is why the family owns airport terminals, museum atria and signature entrances.

The spider glazing vs framed systems comparison comes down to where the load path runs and what it costs. Framed walls spread load along continuous profiles; point-support concentrates it into each fixing, so glass thickness climbs to 8 or 12 mm laminated and the hardware, spiders, tensioning and secondary steel, pushes the installed rate to two or three times a framed wall. Fitting types and their trade-offs are compared in our spider fittings versus planar systems guide.
The decision factors that actually settle it
Four factors nominate the family before any brochure does. Span: anything beyond about 3.5 m of clear unsupported height pushes toward fins or point-support. Wind: high-wind sites thicken glass in every family, but point-fixings are the most sensitive to thickness change, designed under the procedures in ASTM E1300. Budget: framed walls are the cheapest at repetitive scale, point-supported the dearest. Maintenance: frames can be re-gasketed, points need sealant inspection at every fixing, and all-glass fins need overhead access planned from day one. A glass curtain wall selection made against these four factors survives value engineering; one made from a rendering does not.
One glass curtain wall, three families on stage: the delivered theatre
Public buildings rarely commit to a single family. The delivered Maoming City Theatre envelope, a 4,600 m² curved glass and stone composition on a four-storey civic theatre in Guangdong completed in 26 weeks ex-works, runs a framed glass curtain wall as a continuous green-tinted Low-E band behind vertical stone fins, while the glazed civic base opens the foyer and five cinema halls to the plaza. Starveil Facade engineered and installed it under a single design-supply-installation contract, so the curved geometry, the fins and the glazing carried one warranty chain.

The lesson for buyers is in the mix. The repetitive framed sections did the insulated work at controlled cost, and the curved and transition zones were engineered as defined specials rather than improvised on site. Families were chosen bay by bay against span and exposure, which is the selection logic this guide describes.
What to verify before you commit to a family
Ask any supplier three questions. First, show the calculations: fin or mullion sizing, patch fitting test reports, structural silicone adhesion records. Second, name the family in the specification, not the brand, so substitution during value engineering cannot quietly change the load path. Third, mock-up the worst condition in the chosen family, the tallest fin, the largest point-fixed pane, the structurally glazed corner, before production. A quotation that answers all three in writing is one you can take to contract. Delivery evidence, packing lists and material certificates, then travels with the units instead of behind them.
Send the span, the wind and the view you cannot lose
Send the elevation drawings, the clear height of each opening, the site wind zone, and whether the interior behind the glass is conditioned. From those, the Starveil Facade engineering desk returns a glass curtain wall family recommendation with the load calculations behind it, a glass build-up, and a mock-up scope naming the worst condition on your elevation. Concept-stage drawings are enough to start.
What to carry forward
- Three families: all-glass on fins, framed on aluminium, point-fixed on spiders. Span and wind nominate, budget confirms.
- A glass curtain wall specification names the family, not the brand.
- Frameless means no thermal break in the fin: address condensation at the design stage, not after handover.
- Point-supported transparency is bought with glass thickness and an inspection duty at every fixing.
- Mixed-family envelopes work when each family’s calculations and warranties exist separately.
Frequently asked questions
What are the main types of glass curtain wall?
Three families: all-glass walls held on glass fins and patch fittings, framed walls in visible or structurally glazed aluminium grids, and point-supported walls on spider fittings or tensioned structures. Every system on the market belongs to one of them, so the family is the first line of any specification.
How much more does a point-supported glass wall cost?
Installed rates typically run two to three times a framed wall of the same area, driven by laminated thickness, spider hardware and the steel or cable back-up structure. The premium buys spans up to 20 m and an uninterrupted view; where neither is needed, a framed or structurally glazed wall delivers a similar look for less.
Is a frameless all-glass wall suitable for high-wind sites?
Yes, when it is engineered for the zone. Fin depth and laminate build-up grow with wind load, patch fittings are tested assemblies rather than generic hardware, and deflection limits are verified in the mock-up. A frameless glass curtain wall on an exposed site is a calculated object or it is a liability; what cannot be engineered away is the maintenance duty, since inspections and re-gasketing run from access equipment.
Can one building mix more than one glass curtain wall family?
Yes, and civic buildings often do. On the delivered Maoming City Theatre envelope, a 4,600 m² curved glass and stone composition for a four-storey theatre completed in 26 weeks ex-works, a framed Low-E band works behind stone fins while the glazed civic base opens the foyers to the plaza. Each zone was calculated and warranted separately, so the mix never blurred responsibility.
Do spider fittings weaken the glass?
They concentrate load, which is a different problem. Countersunk fixings remove material from each ply, so point-supported glass is specified laminated and often heat-treated, with hole positions and edge distances fixed by calculation rather than site convenience. Failures at points almost always trace to uncalculated hole positions, not the fitting itself.
How are doors handled in a glazed envelope?
Openings are engineered into the wall, not cut into it afterwards. Doors sit in sub-frames or thermally broken transition frames that carry their own movement and drainage duties, and the door schedule should arrive with the wall drawings so both are tested together in the mock-up.
RELATED READING
Choosing a glass curtain wall system requires more than comparing appearance and upfront cost. For a broader overview of framing routes, glass build-ups and facade details, explore our curtain glazing systems guide. If your project involves large unsupported glass spans or transparent entrances, our guide to frameless facade wind and seismic loads explains how glass fins, structural joints and fixings respond to wind pressure and building movement. For framed systems, see our curtain wall mullion design guide to understand how span, wind load and deflection determine aluminium profile selection. You can also read our guide to structural glazing for villas and pavilions for a closer look at glass-fin-supported and point-supported systems, fixing methods and their engineering requirements.