Two weathertightness philosophies, one panel palette

AspectOpen-joint rainscreenSealed system
Weather logicCavity and drainage manage water that passes the jointsThe outer seal line must stop all water
Typical joint6 to 12 mm open, backed by a ventilated cavityClosed with gasket or sealant; zero misses allowed
MovementAbsorbed at every joint by designConcentrated at designed movement joints only
DryingVentilated cavity dries ingress and flushes condensationTrapped moisture stays until it finds a way out
Workmanship riskLow per metre; physics does the workHigh per metre; one bad seal is the leak
Where it belongsMost new commercial and residential envelopesSmall envelopes, budget work, compatible local codes

The table explains why aluminium cladding systems have moved toward the open joint on new commercial work: the failure mode of a drained cavity is a wet cavity that dries, while the failure mode of a seal is a leak that compounds. Rainscreen cladding systems still demand engineering: cavity depth, ventilation paths and the fixing schedule all need drawings, not habits.

Open joint or sealed: the primary fork

An open-joint system accepts that some water passes the panel face and manages it behind: a cavity of at least 25 to 50 mm, ventilation at head and sill so the cavity dries, and drainage at every horizontal closure. Joint widths of 6 to 12 mm are typical, wide enough to defeat capillary action and to hide the movement the panels will make. Sealed systems put the whole weather burden on the outer line, which concentrates risk: one missed seal among thousands becomes the leak the building is known for. Most new commercial work now specifies the drained and ventilated route.

Joint width and the three axes of movement

Aluminium grows about 23 micrometres per metre for every kelvin of temperature swing, which is near 1.7 mm across a 1.2 m panel over a 60 K facade temperature range. Every panel therefore needs allowance in three axes: length and width for expansion, and out-of-plane for wind deflection and structure tolerance. Open joints absorb the first two axes in every gap; slotted fixing holes and bracket adjustment take the third. Joint widths are where aluminium cladding systems absorb that growth, and a quotation that prices panels without pricing joint movement has not removed the movement, it has moved it to the dispute stage.

Hanging the panel: three fixing logics

Point fixing uses tabs or spigots at the panel returns: cheapest, visible, and best on small formats. Hook-on rails hang each panel from continuous interlocking profiles: fast to install, demountable panel by panel, and the default for large commercial rainscreens. Undercut anchors bolt through the panel face into expanded sockets in the sheet: the strongest hold and the cleanest face, at the highest cost per panel. All three logics appear across aluminium cladding systems in combination, and all three need three-axis adjustment at the bracket. The bracket-to-structure side is an anchoring question in its own right, covered in our curtain wall anchoring guide and, for salt air, our coastal structural glazing fixing methods note.

Hook-on rail and bracket with three-axis adjustment carrying an aluminium panel on a subframe

Substructure: the frame behind the family

The carrier frame is extruded aluminium, 6063 typically, or galvanised steel, and the choice is engineering rather than habit: aluminium is lighter and matches the panel thermally, steel is stiffer per kilo and cheaper on long spans. Where the two metals meet, isolators prevent galvanic corrosion; where the frame crosses the thermal line, thermal breaks keep the cladding from becoming a cooling fin. Conversion brackets tie the whole frame back to slabs or primary steel and absorb the structure’s real tolerances. Aluminium cladding systems fail at the conversions more often than at the panels, which is why the bracket schedule deserves the same review as the panel finish.

Composite cores and the fire question

Aluminium composite panel thickness is standardised: two 0.5 mm aluminium skins on a core, 3 to 4 mm total, and the core is the fire question. Polyethylene cores are restricted or banned on regulated envelopes in most major markets; mineral-filled cores rated A2, or non-combustible A1 constructions, are the compliant route, with reaction to fire classified under EN 13501.

	Cutaway of aluminium composite panel showing 0.5 mm skins over a mineral fire core

The core is also why aluminium cladding systems are specified as panel and chain together: a compliant core in an unengineered fixing is still a non-compliant wall. Ask for the core class declaration and the fire test evidence per panel batch, in writing, before the deposit.

The riverside record: cladding for a first-time crew

A study on record for the Baghdad riverside residence, an 860 m² envelope that pairs a full-height stick curtain wall to the river with a deeply recessed perforated screen on the street side, shows how aluminium cladding installation is engineered for real sites. The package was fabricated under staged QA photography and packed in installation sequence, so the client’s crew could work bay by bay without sorting material, and our installation engineer spent two weeks on site setting out the first grid and signing off the first panels before the crew continued alone. Sixteen weeks ex-works, PVDF-coated framing against 50 °C summers and dust seasons, pressure-equalised joints throughout: the finish logic is in our PVDF coating guide, and the wider climate specification in our salt and sand durability guide.

Send the envelope, ask for the chain.

Send the elevations and the areas flagged for panel zones, the exposure data, and the local fire code the envelope must satisfy. Ask back for the joint strategy with widths, the fixing schedule per panel type, the cavity and drainage drawings, the substructure and bracket specification, and the core class declaration on any composite. Starveil Facade returns aluminium cladding systems documentation in exactly that structure from the Foshan engineering desk.

What to carry forward

  • The joint decides the system: drained and ventilated is the default for new commercial work.
  • Movement is arithmetic: about 23 µm per metre per kelvin, three axes, allowed at every joint or at the dispute stage.
  • Fixing logic is a cost dial: point fixing, hook-on rail, undercut anchor, each priced per panel.
  • Aluminium cladding systems are bought as a chain: panel, fixing, cavity, anchor, one warranty conversation.
  • Failures start at conversions and anchors, not at panel faces; review the bracket schedule like the finish.
  • Composite core class is a code line item: A2 mineral or better on regulated envelopes.

RELATED READING

For a broader understanding of aluminium facade solutions, explore the Starveil Facade homepage for an overview of facade systems, engineering capabilities and project applications. If you are comparing panel types and material options, our aluminium facade systems guide explains the differences between solid aluminium sheet, composite, perforated and honeycomb panels. For projects requiring reliable structural connections, the curtain wall anchoring guide covers anchor types, bracket adjustments and load transfer. You can also refer to our PVDF coating guide to understand coating specifications, AAMA performance classes and long-term facade durability in demanding environments.

الأسئلة الشائعة

How do open-joint aluminium cladding systems keep water out?

They do not keep it out; they manage it. Water that passes the open joints meets a ventilated cavity, drains at engineered closures and dries in the airflow. The panel face is a rain screen, the cavity is the weather logic, and the inner line is the air seal.

What joint width do aluminium cladding systems need?

Six to 12 mm on open-joint aluminium cladding systems, set by the panel’s thermal movement and the capillary limit, and confirmed against the fixing slot clearances. Sealed systems close the joint entirely and take movement at designed joints instead.

Are aluminium cladding systems with composite panel still allowed on facades?

Yes, with the right core. Most regulated markets restrict polyethylene-core panel and accept mineral-filled A2 or non-combustible A1 constructions, classified under EN 13501. The declaration and the fire test evidence should be per batch, in writing, before any deposit moves.

How much movement must the fixing system allow?

About 23 micrometres per metre per kelvin in aluminium: near 1.7 mm on a 1.2 m panel across a 60 K range, plus wind deflection and structure tolerance out of plane. Slotted holes, bracket adjustment and joint widths are the three places that allowance lives.

Can a local crew install the panels without specialist experience?

Yes, when the system is engineered for it. The Baghdad riverside residence study on record, an 860 m² envelope with a perforated street screen, was packed in installation sequence, and a supervised start-up of two weeks let the client’s own crew continue alone, within a 16-week ex-works programme.

Does the scope include the substructure?

It must, or it is not a system. Panel, carrier frame, conversion brackets, cavity closers and anchor fixings form one load path and one warranty conversation; buying the panels alone and improvising the frame on site is where cladding programmes lose both their programme and their responsibility map.

عن الكاتب

Leo

Leo

أدير أرض المصنع وسجلات ضمان الجودة التي ترافق كل ما يخرج منه — كل وحدة جدار ستائري ووحدة زجاج وقطاع ألمنيوم مبثوق يُصنَّع وفق المواصفات، ويُفحص في كل مرحلة، ويُعبَّأ بالترتيب الذي يركّب به فريقك في الموقع.

لماذا تثق بي:

أكثر من 15 عامًا في تصنيع الألمنيوم وإنتاج الجدران الستائرية
الخبرة الأساسية: التشغيل الآلي CNC، وضمان الجودة على مستوى الوحدة، والتعبئة للتصدير، وتحميل الحاويات
أسّس نظام توثيق ضمان الجودة وفق ISO 9001 لدى Starveil من البداية
المسؤول المسمّى عن سجلات فحص الوحدات المرفقة بكل شحنة